2. Safety Assessment

Project Number

Client

Company

Revision

16776

​

Bector Automation RML India Pvt. Ltd.

0

Encube Ethicals Private Limited

Introduction to General Safety:

Where appropriate, it is intended that this equipment complies by the guidelines presented in

  • AS4024 - Safety of Machinery [1]

  • BS EN415-7:2006 - Safety of Packaging Machinery [2]

  • ISO 13849:2006 Safety-Related Parts [3]

  • and/or IEC 62061 Safety of Machinery [4]

The supplied Bottle Case Packer (Project No. 16776), installed at Encube Ethicals Private Limited, is a fully automatic packaging system incorporating servo motion control, pneumatic systems, and robotic automation through two robots, RS4-2057504 and RS4-2055004. The machine is designed for high-speed and accurate packaging operations within a pharmaceutical manufacturing environment.

The complete equipment is considered as a single integrated safety cell. Fixed perimeter guarding is provided around all hazardous machine and robot areas, while access for maintenance, inspection, troubleshooting, and fault recovery is provided through interlocked guard doors. A boom barrier system is also provided for controlled access to the designated area.

The machine safety system includes interlocked guard doors, safety PLC functions, emergency stop circuits, and the boom barrier arrangement. Activation of any safety device initiates a safe stop condition and prevents hazardous movement of the machine and robots.

During normal production, personnel are prevented from accessing hazardous areas, ensuring safe separation from moving machine components and robotic systems.

The proposed guarding layout is illustrated below. Fixed guarding is indicated by red lines, while controlled access points (doors) protected by interlock switches are shown in blue and the boom barrier are shown in Orange.

Figure 2: Guarding Arrangement

1.Electrical And Control Systems

1. Electrical and Control Systems

Bector Automation RML Engineering India Pvt. Ltd. representatives have conducted a detailed and systematic Risk Assessment to identify, analyze, and mitigate potential hazards associated with the machine. The assessment has been carried out in line with internationally recognized safety practices and guidelines.

The electrical control panel is equipped with Lock Out / Tag Out (LOTO) provisions to ensure safe and complete isolation of all energy sources during maintenance and servicing activities. This includes electrical, pneumatic, and mechanical energy, thereby preventing any unintended machine start-up.

The risk assessment document systematically evaluates each section of the machine by assigning a Hazard Rating Number (HRN) to every identified hazard. This rating is derived based on the severity of injury, frequency and duration of exposure, and probability of occurrence. Hazards with higher HRN values represent more critical risks and are prioritized for implementation of appropriate risk reduction measures.

Appropriate safeguards such as fixed guarding, interlocked access doors, emergency stop systems, safety-rated control circuits, and procedural controls have been implemented to minimize risks. These measures ensure that all identified hazards are reduced to an acceptable level, providing a safe and reliable working environment for operators and maintenance personnel.

2.General Requirements

2. General requirements

As mentioned previously, with the exception of conveyors, operation and maintenance staff are separated from the moving and hazardous parts of the machine by the guard structure when the machine is energized. Access to the internal parts of the machine can only be possible when the machine has been de-energized, and the machine is deemed to be in a “Safe state”. For this reason, the safety system shall be designed and implemented to serve the sole function of de-energizing all moving or hazardous equipment when a non "Safe State" is detected.

With reference to Figure.2, and the required levels of protection (SIL 2 and PL(d)), the components required to make the safety control system will be a safety controller, safety contactors, emergency stops, door switches, photoelectric sensors and a safety air service unit. The devices within the safety control system are expected to respond, and the safety system switch, to a safe state within 0.8 seconds of any potential fault detection or safety function demand. Maximum fault detection time (i.e., determining the difference between device fault or safety function actuation) should be no more than 3 seconds. These values are determined from experience with similar machinery.

Considerations during the design phase in respect to the operating environment of the machinery were made.

  • The machinery due to its function and operating environment will not be subject to shocks or vibrations.

  • Electromagnetic compatibility is adhered to by installation of electrical components undertaken by qualified personnel.

  • The machine is designed for a non-wash down food packing environment.

  • Material selection and professional design solutions have been implemented to ensure mechanical durability.

  • It is expected the machine will be operating in ambient room temperature.

Correct maintenance of machinery componentry, both mechanical and electrical is outlined in the machinery manual that is supplied with the Stride.

Above and beyond the manufacture certifications of the devices used, correct installation and implementation of devices must be adhered too. Fault detection should cover, but is not limited too

  • Cross circuits

  • Short circuits

  • Open circuits

  • Cross terminals

2.1.HAZOP

2.1 HAZOP (Risk Assessment)

HAZOP, or a Hazard and Operability Study, is a systematic way to identify possible hazards in a work process. In this approach, the process is broken down into steps, and every variation in work parameters is considered for each step, to see what could go wrong. Please refer the below attachment for HAZOP Document.

  • 16776- Risk Assessment

2.2.Safety Contactor

2.2 Safety Contactors

SAFETY.png

Note: Click on the Image for the Component Manual

Safety contactors are used to isolate power to specific devices within the machine. The safety contactors work in conjunction with the safety controller, so that when an un-safe state is detected by the safety controller, the safety contactors work to isolate all relevant devices to allow the machine to reach a safe state. Below are the part details and a reliability block diagram (RBD) of the safety contactors to demonstrate the required architecture.

image.png

Figure.5: Safety contactor RBD

Table.4: Safety contactor part data

Description

Part No.

Quantity

Target PL

Schneider Safety Contactors

LC1D18BD

1

d

2.3.Door Switches

2.3 Door Switches

35-stm-series-solenoid-locking-safety-switch-1024x1024.jpg

Click on the Image for the Component Manual

Doors are designed to restrict access into all areas where there is potential for contact with moving machinery. Access to these areas should only be allowed when the motion has stopped. All equipment is energized via the safety circuit; therefore, the safety function of the door switches is to identify access to these areas is possible by turning the safety system to a non-safe state which in turn de-energizes all machinery. Below are the part details and a reliability block diagram of the door switches to demonstrate the required architecture.

Safety Wiring.png

Figure.7: Door switch RBD

Table.5: Door switch part data

Description

Part No.

Quantity

PL

Safety Door Switch

STM2N-2222B024-L01-M

3

d

2.4.Photoelectric Sensors

2.4 Photoelectric sensors

Click on the Image for the Component Manual (pepperl-fuchs)  216895

The photoelectric sensor is implemented as a safety device to monitor the case blank infeed area. It verifies the presence of material before permitting machine operation. In the absence of detection, the system interprets the condition as unsafe and immediately communicates with the safety controller to inhibit or stop the machine. This arrangement ensures that the sensor functions as a critical safety element within the system.

Description

Part No.

Photoelectric sensors

GTB6-P4231

Table.6: Photoelectric sensor part data

2.5.Safety Monitored Air Service Unit

2.5 Safety Monitored Air Service Unit

A number of the moving parts within the machinery supplied are pneumatically operated. Actuation of these pneumatic devices are electrical, however the energy associated with the mechanical movements is pneumatic. As mentioned previously, to ensure complete de-energizing of the equipment, all pneumatic devices must have their energy removed. A safety monitored dump valve is expected to achieve this if signaled to do so by the safety controller. Below are the part details and a reliability block diagram of the safety dump valve to demonstrate the required architecture.

Figure.: Air service unit RBD

Description

Part No.

Quantity

PL

Pressure Switch with Filter

MSB61/2: C4:J19:F1:V38-WP-Z

1

d

MS6-FRM-1/2-Z

MS6-LFR-1/2-D6-C-R-M-AD1-AS-Z

MS6-EM1-1/2-S-Z

1

1

1

Table.7: Air service unit part data

3. Validation

3. Validation

Upon completion of the design and manufacture of this equipment, the design of the safety related parts of the control system shall be validated by a third party in accordance with AS 4024 [1], ISO 13849 [3] and/or IEC 62061 [4]. This document will form the basis for the validation by identifying the safety functions affecting the machinery supplied by Bector Automation RML India Pvt Ltd

4. Conclusion

4. Conclusion

Encube Ethicals Pvt. Ltd. is a pharmaceutical manufacturer. Bector Automation RML Engineering India Pvt. Ltd. has been assigned to provide an automated solution to replace the existing manual case-packing operation on the packaging line.

The proposed solution is an Adjustable Bottle Case Packer, designed to handle multiple bottle and case packaging formats efficiently. The system aims to reduce manual intervention, improve packing consistency, increase productivity, and enhance the overall efficiency of the packaging line.

The scope of the project required a number of safety standards be adhered to, in particular AS4024 [1], BS EN415 [2], ISO 13849 [3] and IEC 62061 [6]. The machine is designed to be fully automatic; therefore, where permanent guarding is not practical, control systems are used to safeguard operation staff from any identified hazards (Appendix.1). The degree of safeguarding for this control system was determined to be PLd by systematic analysis using the Risk Analysis assessment with the exception of the case in feed which is to be designed in accordance with BS EN 415 [2] and have a SIL2 level of protection. The safety system implemented will serve the sole function of de-energizing all conveyor motors, servo motors, pneumatic cylinders in the event of an un-safe state. Because the machinery is fully automatic, the unsafe state is when operation staff can be exposed to any moving parts. It is required that the safety control system be validated upon completion of design, manufacture and assembly. Validation will be carried out internally by a person independent of the design of the safety systems.

5. References

5. References

[1] European Committee For Standardization, BS EN 415-7:2006 +A1 2008 Safety Of Packaging Machines